AF910 Manual Version 1.4 Page 35
Mechanical Dimensions
Electrical Specifications and Connections
The AF91x requires 12 VDC power at 300mA to operate. It is important that 12 VDC
power not vary by more than +/- 200mV or damage to the unit may occur.
Main Sensor Connection
Connector Type(s): Molex Milli-Grid (ribbon cable type), # 87568-3063 or Molex Milli-
Grid (crimp style), #51110-3051 and contacts #50394-8100.
Pin
Name
Type
Description
1
+12VDC
Power
Positive supply voltage (350mA)
2
GND
Power
Ground
3
+12VDC
Power
Positive supply voltage (350mA)
4
GND
Power
Ground
5
N/C
N/A
No connection
6
N/C
N/A
No connection
7
N/C
N/A
No connection
8
N/C
N/A
No connection
9
GND
Power
Ground